Toll-free:1-888-852-8623

All categories

  • All categories
  • Flow Cytometry Antibodies
  • ELISA Kits
  • MACS Cell Isolation
  • Antibodies and Reagents
  • Apoptosis and Cell Health Detection
  • Metabolism Assays
  • Immunoassays
  • Cell Identification Kits
  • Proteins and Peptides
  • Cell Culture
Please enter the item number/product keyword!
Keyword cannot be empty !
INSERT SYMBOLS:
  • α
  • β
  • γ
  • δ
  • ε
  • ζ
  • η
  • θ
  • κ
  • μ
  • ω
  • σ
  • τ
  • λ
  • ⅩⅢ
  • ⅩⅢ
  • ⅩⅣ
  • ⅩⅤ
  • ⅩⅦ
  • ⅩⅧ
  • UP ↑

Total Iron Binding Capacity (TIBC) Colorimetric Assay Kit (E-BC-K071-M)

All Size Price Qty
96T $ 220.00
48T $ 150.00
Add to cart

For research use only.

Detection Principle The excess iron is added to the serum to bind all the ferritin in the serum, and the excess iron is adsorbed by adding the iron adsorbent. The iron bind with the ferritin is separated from the protein by the action of acid solution and reductant. Fe3+ in serum is reduced to Fe2+, Fe2+ binds with bipyridine to form pink complex. In a certain range, the amount of TIBC is positively correlated with the depth of color. The iron content measured is, minus serum iron value, which is called unsaturated iron binding force. Total iron binding capacity minus serum iron value is unsaturated iron binding capacity (UIBC).
Synonyms TIBC
Sample Type Serum,Plasma
Detection Method Colorimetric method
Detection Instrument Microplate reader (510-530 nm, optimum wavelength: 520 nm)
Research Area Inorganic Ions
Storage This product can be stored at 2-8°C for 12 months with shading light.
Valid Period 12 months
Sensitivity 0.14 mg/L
Detection Range 0.31-50 mg/L
Precision inter-assay CV: 2.3% | intra-assay CV: 1.5%
Sample Volume 50 μL
Assay Time 20 min

The recommended dilution factor for different samples is as follows (for reference only):

Sample Type Dilution Factor
Human serum 1
Rat serum 1
Porcine serum 1
Rabbit serum 1
Chicken serum 1
Machin serum 1

The diluent is normal saline (0.9% NaCl) or PBS (0.01 M, pH 7.4). For the dilution of other sample types, please do pretest to confirm the dilution factor.

Other Clones

{{antibodyDetailsPage.numTotal}} Results

Other Formats

{{formatDetailsPage.numTotal}} Results

  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.organization}}

detection instrument

{{assayDetailsPage.numTotal}} Results

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}