Toll-free:1-888-852-8623

All categories

  • All categories
  • Flow Cytometry Antibodies
  • ELISA Kits
  • MACS Cell Isolation
  • Antibodies and Reagents
  • Apoptosis and Cell Health Detection
  • Metabolism Assays
  • Immunoassays
  • Cell Identification Kits
  • Proteins and Peptides
  • Cell Culture
Please enter the item number/product keyword!
Keyword cannot be empty !
INSERT SYMBOLS:
  • α
  • β
  • γ
  • δ
  • ε
  • ζ
  • η
  • θ
  • κ
  • μ
  • ω
  • σ
  • τ
  • λ
  • ⅩⅢ
  • ⅩⅢ
  • ⅩⅣ
  • ⅩⅤ
  • ⅩⅦ
  • ⅩⅧ
  • UP ↑

Dual Luciferase Reporter Gene Luminescence Assay Kit (Glow Type) (E-BC-F074)

All Size Price Qty
96T $ 220.00
48T $ 150.00
Add to cart

For research use only.

Detection Principle Dual luciferase reporter gene is used to detect the luminescence reaction produced by luciferase catalyzed substrates. The detection system includes firefly luciferase reporter gene and renilla luciferase reporter gene. As an internal parameter of transfection, the renilla luciferase can normalize the experimental data. Firefly luciferase reporter gene refers to a reporting system that uses fluorescein as substrate to detect fluorescein luciferase activity. The reaction can occur in the presence of ATP, magnesium ions and oxygen, resulting in yellow-green fluorescence signals. The advantage of the reporter gene is that the expression product of the reporter gene has detectable enzyme activity as soon as the translation is completed. Renilla luciferase reporter gene refers to a reporting system that uses coelenterazine as substrate to detect the activity of renilla luciferase. This reaction does not depend on ATP to participate in the enzymatic reaction. During the reaction, a blue fluorescence signal is generated.
The reaction principle of this kit is that in the presence of oxygen, ATP and magnesium ions at the same time, firefly luciferin and coelenterazine are catalyzed and oxidized successively by firefly luciferase and renilla luciferase in the samples to produce different fluorescence signals, and the expression levels of firefly luciferase and renilla luciferase in the samples can be detected by chemiluminescence immunoassay analyzer.
Sample Type Cell
Detection Method Fluorometric method
Detection Instrument Chemiluminescence immunoassay analyzer or multifunctional microplate reader (with the function of detecting luminescence)
Research Area Amino Acids And Proteins
Storage This product can be stored at -20°C for 12 months with shading light.
Valid Period 12 months
Assay Time 40 min
Other Clones

{{antibodyDetailsPage.numTotal}} Results

Other Formats

{{formatDetailsPage.numTotal}} Results

Biotin

Chromogenic Biotin

Cyanine 3

Cyanine 5

Cyanine 5.5

Cyanine 7

Elab Fluor® Violet 450

Elab Fluor®430

Elab Fluor®488

Elab Fluor®568

Elab Fluor®594

Elab Fluor®647

Elab Fluor®680

Elab Fluor®700

Elab Fluor®750

Elab Fluor®Red 780

Elab Fluor®Violet 450

FITC

HRP

NHS-Biotin

NHS-LC-LC-Biotin

Sulfo-NHS-Biotin

Sulfo-NHS-LC-LC-Biotin

Unconjugated

  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.organization}}

detection instrument

{{assayDetailsPage.numTotal}} Results

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}